Deutsch (DE-CH-AT)English (United Kingdom)French (Fr)

Annular Tube

Annular Tube

Available in the following dimensions 

DN 12
DN 16
DN 20
DN 25
DN 32
(other sizes are available on request)

Brass union nuts and double nipples. High grade stainless steel (316)

Maximum pressure at 200°C: 10 bar Temperature range: -100°C bis 300°C

Suitable for all standard tube fittings and insulations

Tubes available as rolls which allows for easy transport and storage

Available in 5 m, 25 m and 50 m lengths

Custom made lengths are available on request


Technical Data

WATERWAY
®  high-grade stainless steel tube
Annular type, material 316, machine welded construction
 

DN - R(")
____________
Inside-diameter  
Outside-diameter  
Bendingradius         
static        
Maximum allowed
pressure    
Burst-pressure    

(mm)
(mm) (mm) (bar)
(bar)
10-R3/8"
10,40
13,50
18
10
100
12-R1/2"
12,60
16,00
20
10
90
16-R3/4"
15,60
20,20
25
10
70
20-R1"
20,10
25,50
30
10
60
25-R11/4"
27,00
31,70
35
10
50
 
 
DN - R(")
Wight/M  
Length
Wall thickness
Material
    

(g)
(m) (mm)
pressure
10-R3/8" 110
25
0,3 1,4404
loss
12-R1/2" 160
25
0,3
1,4404
25% more
16-R3/4"
190
25
0,3
1,4404
compared
20-R1" 290
25
0,3
1,4404
to standard
25-R11/4" 330
25
0,
1,4404
tubing
 

Pressure/flow curves


Pressure flow curves based on 1m WATERWAY®-annular tube, medium: Tyfocor: water 40:60 temperature: 40°C



 

Nut with support ring and washer
_____________

    Tube end deburrer
 

Compression fittings

    tube cutter
 

Double nipple male thread

    crimping device
_____________



waterway_Startseite_24 (1K)